Trouble Conditions
Typical Check Displays
The word
CHECK
on the keypad's display, accompanied by a rapid beeping at
the keypad, indicates a trouble condition in the system. The displays in
parentheses in the left column below may appear on non-Alpha keypads when
the associated trouble condition is present.
To silence the beeping sound
for “CHECK” conditions, press any key.
CHECK
+ Zone
number or Descriptors
*
Note: A display of
Zone 9
represents a
problem with the
wireless receiver or
other system devices,
which are not user-
serviceable.
CALL
FOR SERVICE
IMMEDIATELY
Indicates that a problem exists with those zone(s).*
First, determine why the zone(s) displayed are
faulted (open window or door; open or shorted zone
terminals; etc.) and correct the problem. If the
zone(s) contain a wireless detector, check that
changes in the room (moving furniture, televisions,
etc.) are not blocking wireless signals to/from the
detector.
If the problem has been corrected, the zone
descriptor(s) and CHECK should disappear.
To clear the display if not corrected, key an OFF
sequence (enter the 4-digit security code, then press
the OFF key.
A
CHECK
condition can also indicate a wiring
problem (opens or shorts, for instance). If the
CHECK
display persists,
CALL FOR SERVICE
IMMEDIATELY.
Note that the system will not allow arming if a
CHECK
condition exists. To arm the system with a
CHECK
condition present, you must first bypass
the zone(s) having the
CHECK
condition.