Specifications
SL150 SECURITY CONTROL
1. Physical:
12-1/2” W x 14-1/2” H x 3” D (318mm x 368mm x 76mm)
2. Electrical:
VOLTAGE INPUT: 16.5VAC from plug-in 25VA transformer, Ademco No. 1321 (in
USA), or Powerline Carrier device Interface AC Transformer if
Powerline Carrier devices are being used.
RECHARGEABLE
BACKUP BATTERY:
12VDC, 4AH (Sealed Lead Acid). Charging Voltage: 13.8VDC.
For actual battery size needed, refer to Section 12, FINAL
POWER-UP (see “Calculating the Battery Size needed”).
ALARM SOUNDER: 12V, 2.0 Amp output can drive 12V BELLS or can drive one or
two 702 (
series
connected) self-contained 20-watt sirens. Do
not
connect two 702s in parallel.
AUXILIARY POWER
OUTPUT:
12VDC, 600mA max (500mA max for UL installations).
Interrupts for 4-wire smoke detector reset.
Note: For UL installations, Alarm Sounder plus Auxiliary
Power currents should not exceed 600mA total.
STANDBY TIME: (see Table in
Section 12: Final Power-Up)
FUSE: Battery (3A) No. 90–12
3. Communication:
FORMATS SUPPORTED:
Ademco Express:
Ademco Contact ID
Reporting:
Ademco Low Speed:
Radionics/SESCOA:
10 characters/sec, DTMF (TouchTone) Data Tones, 1400/2300Hz
ACK, 1400Hz KISSOFF.
10 characters/sec., DTMF (TouchTone) Data Tones,
1400/2300Hz ACK, 1400Hz KISSOFF.
10 pulses/sec, 1900Hz Data Tone, 1400Hz ACK/KISSOFF.
20 pulses/sec, 1800Hz Data Tone, 2300Hz ACK/KISSOFF. Can
report 0–9, B–F
Line Seize: Double Pole;
Ringer Equivalence: 0.7B;
FCC Registration No.: AC 398U–68192–AL–E
4. Maximum Zone
Resistance:
Zones 1–8 = 300 ohms excluding EOLR