SL150 Installation and Setup Guide
17–2
2. Zone List (ZL) is a group of zones to which the event applies in order to
activate a particular device. Note that there are 3 output device-related
zone lists that can be programmed in
✱
81 Menu mode; when the selected
event (alarm, fault or trouble) occurs in any zone in the selected
Start
zone list (1, 2, or 3), activation of the selected device will
Start
.
Start by Zone Type or System Operation
1. If a System Operation, such as disarming or
any
fire alarm
,
is to
activate the device, the appropriate choice would also be entered under
the ZONE
TYPE option. ZONE TYPE is used independently of the
“EVENT/ZONE LIST” combination.
If a ZONE TYPE is chosen, any zone of that response type going into
alarm, trouble, or fault will cause the device to activate as selected in
“ACTION.” If the same ZONE TYPE is also chosen for the Stop
programming, any zone of that type that restores will deactivate the
device.
If a
System Operation
is chosen (for example, end of exit time), that
operation will cause the device to activate as selected in action. The
different choices for ZONE TYPE and
System Operation
are listed in
“Programming Output Relays and Powerline Carrier Devices” later in this
section, and in the Programming Form.
STOP (STP):
The
Stop
programming determines when and under what conditions the
device will be deactivated. The following options are available:
Upon Restore of a Zone List
1. Restore Zone List (ZL): If a ZONE LIST is used as the Stop event, the
device will deactivate when all the zones in that list restore from a
previous fault, trouble, or alarm condition. This will occur regardless of
what is programmed to
Start
the device; therefore, a "RESTORE ZONE
LIST" would normally only be used when a ZONE LIST is used to
Start
the device.
Upon a Zone Type or System Operation
1. Zone Type/System Operation: Instead of using a "RESTORE ZONE
LIST", a specific zone (response) type or system operation action can be
selected to deactivate the device.
If a specific ZONE TYPE is chosen, any zone of that response type that
restores from a previous alarm, trouble, or fault condition will cause the
device to deactivate.
If a
System Operation
is chosen, that operation will cause the device to
deactivate. The different choices for ZONE TYPE and
System
Operation
are listed in “Programming Output Relays and Powerline
Carrier Devices” later in this section, and in the Programming Form.
During normal system operation,
you may start any devices manually by a keypad entry of:
Code + # + 7 + n
or stop them manually by a keypad entry of:
Code + # + 8 + n,
where n = the
device number to be controlled.
As a minimum, the ACTION (A) field must be programmed for this manual action to be operative.