Section 14 - Zone Response Type Definitions
14–3
Type 10
Interior w/Delay
This zone type gives
Entry Delay
(using the programmed entry
time), if tripped when the panel is armed in the AWAY mode. Entry
Delay begins whenever sensors in this zone are violated, regardless
of whether or not an Entry/exit Delay zone was tripped first. No
Entry Delay is provided if tripped when the panel is armed in the
MAXIMUM mode. Exit Delay is present for any arming mode. This
zone type is bypassed when the panel is armed in the STAY
or INSTANT mode.
Type 14
24-Hour CO Monitor
This is a special zone type assigned to any zone with a carbon
monoxide detector. The bell output will pulse when this zone type
is alarmed. This zone type is always active and cannot be bypassed.
Type 15
24-hour
Medical Alarm
This zone type sends a report to the Central Station and provides
an alarm sound at the keypad. (No bell output is provided). This
zone type is usually assigned to a zone containing a button for use
in medical emergencies.
Type 20
Arm-STAY
This is a special-purpose zone type, used with 5800 Series Wireless
Pushbutton units, which will result in arming the system in the
STAY mode when the zone is activated. Pushbutton units send the
zone number as a user number to the Central Station when arming
or disarming.
Type 21
Arm-AWAY
This is a special-purpose zone type, used with 5800 Series Wireless
Pushbutton units, which will result in arming the system in the
AWAY mode when the zone is activated. Pushbutton units send the
zone number as a user number to the Central Station when arming
or disarming.
Type 22
Disarm
This is a special-purpose zone type, used with 5800 Series Wireless
Pushbutton units, which will result in disarming the system when
the zone is activated.
Type 23
No Alarm Response
This zone type can be used on a zone when an output relay action is
desired, but with no accompanying alarm (e.g., lobby door access).
Type 24
Silent Burglary
Type 64
One-Button Page
This zone type provides an instant alarm, with no audible
indication at any keypad or external sounder, if the zone is faulted
when the system is armed in the AWAY, STAY, INSTANT, or
MAXIMUM mode. This zone type is usually assigned to all sensors
or contacts on exterior doors and windows where bells and/or sirens
are NOT desired. A report is sent to the Central Station.
This zone type allows sending one-button paging from a wireless
key fob. It will send a predefined message that will be different
from keypad one-button paging. Paging from a wireless key fob
sends999–9998”.
NOTE:
All of the zone types described are available for the wireless portion of the system, if
used.